  1. Pubblicazioni

Microelectrode Arrays of Diamond-Insulated Graphitic Channels for Real-Time Detection of Exocytotic Events from Cultured Chromaffin Cells and Slices of Adrenal Glands

Articolo
Data di Pubblicazione:
2016
Abstract:
A microstructured graphitic 4 × 4 multi-electrode array was embedded in a single-crystal diamond substrate (4 × 4 μG-SCD MEA) for real-time monitoring of exocytotic events from cultured chromaffin cells and adrenal slices. The current approach relies on the development of a parallel ion beam lithographic technique, which assures the time-effective fabrication of extended arrays with reproducible electrode dimensions. The reported device is suitable for performing amperometric and voltammetric recordings with high sensitivity and temporal resolution, by simultaneously acquiring data from 16 rectangularly shaped microelectrodes (20 × 3.5 μm2) separated by 200 μm gaps. Taking advantage of the array geometry we addressed the following specific issues: (i) detect both the spontaneous and KCl-evoked secretion simultaneously from several chromaffin cells directly cultured on the device surface, (ii) resolve the waveform of different subsets of exocytotic events, and (iii) monitoring quantal secretory events from thin slices of the adrenal gland. The frequency of spontaneous release was low (0.12 and 0.3 Hz, respectively, for adrenal slices and cultured cells) and increased up to 0.9 Hz after stimulation with 30 mM KCl in cultured cells. The spike amplitude as well as rise and decay time were comparable with those measured by carbon fiber microelectrodes and allowed to identify three different subsets of secretory events associated with “full fusion” events, “kiss-and-run” and “kiss-and-stay” exocytosis, confirming that the device has adequate sensitivity and time resolution for real-time recordings. The device offers the significant advantage of shortening the time to collect data by allowing simultaneous recordings from cell populations either in primary cell cultures or in intact tissues.
Tipologia CRIS:
03A-Articolo su Rivista
Keywords:
Diamond, Multielectrode array, Cell sensing
Elenco autori:
Picollo, Federico; Battiato, Alfio; Bernardi, Ettore; Marcantoni, Andrea; Pasquarelli, Alberto; Carbone, Emilio; Olivero, Paolo; Carabelli, Valentina
Autori di Ateneo:
CARABELLI Valentina
CARBONE Emilio
MARCANTONI Andrea
OLIVERO Paolo
PICOLLO Federico
Link alla scheda completa:
https://iris.unito.it/handle/2318/1589408
Link al Full Text:
https://iris.unito.it/retrieve/handle/2318/1589408/207356/AC_88_7493_AperTo.pdf
Pubblicato in:
ANALYTICAL CHEMISTRY
Journal