Skip to Main Content (Press Enter)

Logo UNITO
  • ×
  • Home
  • Pubblicazioni
  • Progetti
  • Persone
  • Competenze
  • Settori
  • Strutture
  • Terza Missione

UNI-FIND
Logo UNITO

|

UNI-FIND

unito.it
  • ×
  • Home
  • Pubblicazioni
  • Progetti
  • Persone
  • Competenze
  • Settori
  • Strutture
  • Terza Missione
  1. Pubblicazioni

Developing strategies to reduce spray drift in pneumatic spraying in vineyards: Assessment of the parameters affecting droplet size in pneumatic spraying

Articolo
Data di Pubblicazione:
2018
Abstract:
Pneumatic sprayers are widely used in vineyards due to their very fine droplet size, which, on the other hand, makes the drift risk to become an important problem to be considered. The aim of this study was to assess the effect of the spout diameter on the spray droplet size and uniformity achieved for different liquid flow rates (LFR) and air flow rates (AFR). A test bench was developed to simulate a real pneumatic sprayer under laboratory conditions, and it was empirically adjusted to match the air pressure conditions as closely as possible to real working conditions. Two positions of insertion of the liquid hose, the conventional position (CP) and an alternative position (AP), were tested for three LFRs, 1.00, 1.64, and 2.67 L min-1, and four AFRs, 0.280, 0.312, 0.345, and 0.376 m3 s-1. The air speed decrease between the two insertion points of the liquid hose was measured. A Malvern SprayTec® instrument was used to measure the droplet size, and the D50, D10, and D90 parameter values were obtained. The relative SPAN factor (RSF) was also calculated. A model to predict variations in D50 was fitted using the aforementioned parameters. The results show that a change in the diameter of the spout significantly changes the droplet size, producing a mean increase of 59.45% in D50 and similar increases in D10 and D90. The model developed to predict variations in D50 has a very high degree of accuracy (R2 = 0.945). The relative decrease in the air speed along the spout is constant, with a mean value of 8.35%. The results of the study show that the droplet size produced in pneumatic spraying can be modified easily by varying the air spout dimensions. This should be taken into account by manufacturers from a design point of view.
Tipologia CRIS:
03A-Articolo su Rivista
Keywords:
Pneumatic spraying, Droplet size, Spray drift, Spray technology, Droplet homogeneity
Elenco autori:
MIRANDA FUENTES, Antonio; Marucco, Paolo; González-sánchez, E. J.; Gil, E.; Grella, Marco; Balsari, Paolo
Autori di Ateneo:
GRELLA Marco
MARUCCO Paolo
Link alla scheda completa:
https://iris.unito.it/handle/2318/1652640
Link al Full Text:
https://iris.unito.it/retrieve/handle/2318/1652640/618084/Pre-print_Miranda-Fuentes%20et%20al.,%20Sience%20of%20the%20Total%20Environment,%202018,%20Elsevier.pdf
Pubblicato in:
SCIENCE OF THE TOTAL ENVIRONMENT
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 25.6.1.0