Test beam results with a sampling calorimeter of cerium fluoride scintillating crystals and tungsten absorber plates for calorimetry at the HL-LHC
Articolo
Data di Pubblicazione:
2016
Abstract:
A sampling calorimeter using cerium fluoride scintillating crystals as active material, interleaved with absorber plates made of tungsten, and read out by wavelength-shifting fibres has been tested with high-energy electron beams at the CERN SPS H4 beam line, as well as with lower-energy beams at the INFN Frascati Beam Test Facility in Italy. Energy resolution studies revealed a low stochastic term ( < 100%/root E). This result, combined with high radiation hardness of the material used, marks this sampling calorimeter as a good candidate for the detectors' forward regions during the high luminosity phase of LHC. (C) 2015 Elsevier B.V. All rights reserved.
Tipologia CRIS:
03A-Articolo su Rivista
Keywords:
Beam test; Calorimeter; Cerium fluoride; HL-LHC; Sampling; Tungsten
Elenco autori:
Becker, R; Dissertori, G; Djambazov, L; Donega, M; Droge, M; Haller, C; Horisberger, U; Lustermann, W; Nessi-Tedaldi, F; Quittnat, M; Pandolfi, F; Peruzzi, M; Schonenberger, M; Cavallari, F; Dafinei, I; Diemoz, M; D'Imperio, G; del Re, D; Gelli, S; Lope, CJ; Meridiani, P; Micheli, F; Nuccetelli, M; Organtini, G; Paramatti, R; Pellegrino, F; Rahatlou, S; Rovelli, C; Santanastasio, F; Soffi, L; de Fatis, TT; Martelli, A; Monti, V; Pastrone, N; Trapani, PP; Candelise, V; Della Ricca, G
Link alla scheda completa: