Skip to Main Content (Press Enter)

Logo UNITO
  • ×
  • Home
  • Pubblicazioni
  • Progetti
  • Persone
  • Competenze
  • Settori
  • Strutture
  • Terza Missione

UNI-FIND
Logo UNITO

|

UNI-FIND

unito.it
  • ×
  • Home
  • Pubblicazioni
  • Progetti
  • Persone
  • Competenze
  • Settori
  • Strutture
  • Terza Missione
  1. Pubblicazioni

QuantiFERON® Monitor Test as a Potential Tool for Stratifying Patients by Infection Risk and Tailoring Follow-Up Care in Lung Transplant Recipients: A Single-Center Retrospective Experience

Articolo
Data di Pubblicazione:
2025
Abstract:
Background: Lung transplantation is a life-saving option for patients with end-stage respiratory diseases, but risk of infections remains critical for ensuring long-term organ function. This study aimed to assess immune recovery in lung transplant recipients by measuring IFN-γ levels using the QuantiFERON Monitor Test (QFM). Results were correlated with episodes of infection and organ rejection to explore the assay’s predictive potential. Methods: A retrospective study was conducted on 15 lung transplant recipients at the Lung Transplant Centre of Turin (Città della Salute e della Scienza di Torino, Italy) between December 2019 and January 2023. Patients were divided into a High Infection (HI) group (with >3 infections) and Low Infection (LI) group (with ≤3 infections). QFM assays were performed after 18 months post-transplant. Results: HI patients had lower QFM levels compared to LI (68.84 ± 21.98 vs. 380.54 ± 104.64 UI/mL, p = 0.033). A QFM value <89.5 UI/mL was associated with increased infection risk (p < 0.05). Patients with lower QFM levels also exhibited higher rates of MRSA bacteremia during hospitalization (50% HI vs. 0% LI, p = 0.04). No differences were observed in acute or chronic rejection rates, but LI patients showed more frequent alveolar neutrophilia at the fourth month post-transplant (0% HI vs. 55.5% LI, p = 0.04). Conclusion: lower QFM values were associated with higher infection risk, highlighting the assay’s potential for immune monitoring. In this study, a QFM value of 89.5 UI/mL showed good predictive accuracy for infections beyond 18 months. Further studies are needed to refine QFM’s role in post-transplant care.
Tipologia CRIS:
03A-Articolo su Rivista
Keywords:
immunosuppression; lung transplantation; QuantiFERON Monitor Test
Elenco autori:
Solidoro P.; Curtoni A.; Patrucco F.; Russo E.; Sidoti F.; Piccinini G.; Bondi A.; Valesella P.; Genco M.; Boffini M.; Rinaldo R.F.; Costa C.
Autori di Ateneo:
BOFFINI Massimo
BONDI Alessandro
CURTONI Antonio
GENCO MATTIA
RINALDO Rocco Francesco
SOLIDORO Paolo
Link alla scheda completa:
https://iris.unito.it/handle/2318/2063751
Link al Full Text:
https://iris.unito.it/retrieve/handle/2318/2063751/1607620/QuantiFERON%20Monitor%20Test.pdf
Pubblicato in:
MICROORGANISMS
Journal
  • Aree Di Ricerca

Aree Di Ricerca

Settori (9)


LS6_1 - Innate immunity - (2024)

CIBO, AGRICOLTURA e ALLEVAMENTI - Farmacologia Veterinaria

CIBO, AGRICOLTURA e ALLEVAMENTI - Patologia e malattie degli animali

CIBO, AGRICOLTURA e ALLEVAMENTI - Scienze cliniche veterinarie

MEDICINA, SALUTE e BENESSERE - Epidemiologia

MEDICINA, SALUTE e BENESSERE - Oncologia e Tumori

MEDICINA, SALUTE e BENESSERE - Ricerca Traslazionale e Clinica

MEDICINA, SALUTE e BENESSERE - Trapianti e medicina rigenerativa

SCIENZE DELLA VITA e FARMACOLOGIA - Interazioni tra molecole, cellule, organismi e ambiente
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 25.6.1.0