Skip to Main Content (Press Enter)

Logo UNITO
  • ×
  • Home
  • Pubblicazioni
  • Progetti
  • Persone
  • Competenze
  • Settori
  • Strutture
  • Terza Missione

UNI-FIND
Logo UNITO

|

UNI-FIND

unito.it
  • ×
  • Home
  • Pubblicazioni
  • Progetti
  • Persone
  • Competenze
  • Settori
  • Strutture
  • Terza Missione
  1. Pubblicazioni

A model-independent method for mitigation of pileup artefacts in energy-resolved radiation counting

Articolo
Data di Pubblicazione:
2025
Abstract:
This article presents a model-independent post-processing method to restore the counting and spectral information of pulse-height analyzers in the presence of pulse pileup at high counting rates. The method is based on the measurement of counts and of the integral durations of the detector signals over different thresholds, and on the comparison of the measurements from two sources with the same energy distribution and different counting rates ρ. The procedure does not require the modeling of the pulse shape, the knowledge of the dead-time τ or other parameters. The correction technique was validated with simulations and with spectra of high activity gamma sources collected with a high-purity germanium (HPGe) detector. For a simulated flat energy distribution and a ratio 2 between the two counting rates, the relative mean deviation between the corrected and input spectra is less than 1% and the relative standard deviation below 5% up to a normalized input rate ρτ=1.0. These results improve by increasing the difference between the input rates of the two sources. In the simulation of an X-ray spectrum at a normalized input rate ρτ=0.5, the ratio between the number of corrected and generated counts in each energy bin is below a few percent. The experimental validation was performed by acquiring two spectra of 241Am sources of different activities placed in a fixed position and of a high activity 137Cs source placed in two different position. In both cases, the correction method provides count rate distributions in close agreement with a reference spectrum from a lower activity source. The mitigation of artefacts in HPGe spectra overcomes the performance of a standard pileup rejection method.
Tipologia CRIS:
03A-Articolo su Rivista
Keywords:
Dead time; Gamma spectroscopy; Photon counting; Pulse pileup; Spectrum distortion
Elenco autori:
Monaco, Vincenzo; Durisi, Elisabetta; Monti, Valeria; Visca, Lorenzo
Autori di Ateneo:
DURISI Elisabetta Alessandra
MONACO Vincenzo
MONTI VALERIA
VISCA Lorenzo
Link alla scheda completa:
https://iris.unito.it/handle/2318/2075573
Link al Full Text:
https://iris.unito.it/retrieve/handle/2318/2075573/1886523/1-s2.0-S0168900225000774-main-3.pdf
Pubblicato in:
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT
Journal
  • Dati Generali
  • Aree Di Ricerca

Dati Generali

URL

https://www.sciencedirect.com/science/article/pii/S0168900225000774

Aree Di Ricerca

Settori (2)


PE2_6 - Nuclear, hadron and heavy ion physics - (2024)

SCIENZE MATEMATICHE, CHIMICHE, FISICHE - Cosmologia e Universo
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 25.6.1.0