Design and characterization of the beam monitor detectors of the Italian National Center of Oncological Hadron-therapy (CNAO)

Articolo
Data di Pubblicazione:
2013
Abstract:
A new hadron-therapy facility implementing an active beam scanning technique has been developed at the Italian National Center of Oncological Hadron-therapy (CNAO). This paper presents the design and the characterization of the beam monitor detectors developed for the on-line monitoring and control of the dose delivered during a treatment at CNAO. The detectors are based on five parallel-plate transmission ionization chambers with either a single large electrode or electrodes segmented in 128 strips (strip chambers) and 32×32 pixels (pixel chamber). The detectors are arranged in two independent boxes with an active area larger than 200×200 mm2 and a total water equivalent thickness along the beam path of about 0.9 mm. A custom front-end chip with 64 channels converts the integrated ionization channels without dead-time. The detectors were tested at the clinical proton beam facility of the Paul Scherrer Institut (PSI) which implements a spot scanning technique, each spot being characterized by a predefined number of protons delivered with a pencil beam in a specified point of the irradiation field. The short-term instability was measured by delivering several identical spots in a time interval of few tenths of seconds and is found to be lower than 0.3%. The non-uniformity, measured by delivering sequences of spots in different points of the detector surface, results to be lower than 1% in the single electrode chambers and lower than 1.5% in the strip and pixel chambers, reducing to less than 0.5% and 1% in the restricted 100×100 mm2 central area of the detector.
Tipologia CRIS:
03A-Articolo su Rivista
Keywords:
hadrontherapy; radiation detector; ionization chamber
Elenco autori:
S. Giordanengo;M. Donetti;M.A. Garella;F. Marchetto;G. Alampi;A. Ansarinejad;V. Monaco;M. Mucchi;I.A. Pecka;C. Peroni;R. Sacchi;M. Scalise;C. Tomba;R. Cirio
Autori di Ateneo:
CIRIO Roberto
MONACO Vincenzo
SACCHI Roberto
Link alla scheda completa:
https://iris.unito.it/handle/2318/128978
Link al Full Text:
https://iris.unito.it/retrieve/handle/2318/128978/19922/2013_design_DD.pdf
Pubblicato in:
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT
Journal