Skip to Main Content (Press Enter)

Logo UNITO
  • ×
  • Home
  • Pubblicazioni
  • Progetti
  • Persone
  • Competenze
  • Settori
  • Strutture
  • Terza Missione

UNI-FIND
Logo UNITO

|

UNI-FIND

unito.it
  • ×
  • Home
  • Pubblicazioni
  • Progetti
  • Persone
  • Competenze
  • Settori
  • Strutture
  • Terza Missione
  1. Pubblicazioni

Central pressure appraisal: Clinical validation of a subject-specific mathematical model

Articolo
Data di Pubblicazione:
2016
Abstract:
INTRODUCTION: Current evidence suggests that aortic blood pressure has a superior prognostic value with respect to brachial pressure for cardiovascular events, but direct measurement is not feasible in daily clinical practice. AIM: The aim of the present study is the clinical validation of a multiscale mathematical model for non-invasive appraisal of central blood pressure from subject-specific characteristics. METHODS: A total of 51 young male were selected for the present study. Aortic systolic and diastolic pressure were estimated with a mathematical model and were compared to the most-used non-invasive validated technique (SphygmoCor device, AtCor Medical, Australia). SphygmoCor was calibrated through diastolic and systolic brachial pressure obtained with a sphygmomanometer, while model inputs consist of brachial pressure, height, weight, age, left-ventricular end-systolic and end-diastolic volumes, and data from a pulse wave velocity study. RESULTS: Model-estimated systolic and diastolic central blood pressures resulted to be significantly related to SphygmoCor-assessed central systolic (r = 0.65 p <0.0001) and diastolic (r = 0.84 p<0.0001) blood pressures. The model showed a significant overestimation of systolic pressure (+7.8 (-2.2;14) mmHg, p = 0.0003) and a significant underestimation of diastolic values (-3.2(-7.5;1.6), p = 0.004), which imply a significant overestimation of central pulse pressure. Interestingly, model prediction errors mirror the mean errors reported in large meta-analysis characterizing the use of the SphygmoCor when non-invasive calibration is performed. CONCLUSION: In conclusion, multi-scale mathematical model predictions result to be significantly related to SphygmoCor ones. Model-predicted systolic and diastolic aortic pressure resulted in difference of less than 10 mmHg in the 51% and 84% of the subjects, respectively, when compared with SphygmoCor-obtained pressures.
Tipologia CRIS:
03A-Articolo su Rivista
Keywords:
central pressure, hypertension
Elenco autori:
Tosello, Francesco; Guala, Andrea; Leone, Dario; Camporeale, Carlo; Bruno, Giulia; Ridolfi, Luca; Veglio, Franco; Milan, Alberto
Autori di Ateneo:
MILAN Alberto
VEGLIO Franco
Link alla scheda completa:
https://iris.unito.it/handle/2318/1589144
Link al Full Text:
https://iris.unito.it/retrieve/handle/2318/1589144/577775/61.%20Tosello%20PlosOne%202016.pdf
Pubblicato in:
PLOS ONE
Journal
  • Dati Generali

Dati Generali

URL

http://www.plosone.org/article/fetchObject.action?uri=info:doi/10.1371/journal.pone.0151523&representation=PDF
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 25.6.1.0