Skip to Main Content (Press Enter)

Logo UNITO
  • ×
  • Home
  • Pubblicazioni
  • Progetti
  • Persone
  • Competenze
  • Settori
  • Strutture
  • Terza Missione

UNI-FIND
Logo UNITO

|

UNI-FIND

unito.it
  • ×
  • Home
  • Pubblicazioni
  • Progetti
  • Persone
  • Competenze
  • Settori
  • Strutture
  • Terza Missione
  1. Pubblicazioni

Wearable Inertial Devices in Duchenne Muscular Dystrophy: A Scoping Review

Articolo
Data di Pubblicazione:
2023
Abstract:
In clinical practice and research, innovative digital technologies have been proposed for the characterization of neuromuscular and movement disorders through objective measures. Among these, wearable devices prove to be a suitable solution for tele-monitoring, tele-rehabilitation, and daily activities monitoring. Inertial Measurement Units (IMUs) are low-cost, compact, and easy-to-use wearable devices that evaluate kinematics during different movements. Kinematic variables could support the clinical evaluation of the progression of some neuromuscular diseases and could be used as outcome measures. The current review describes the use of IMUs for the biomechanical assessment of meaningful outcome measures in individuals affected by Duchenne muscular dystrophy (DMD). The PRISMA methodology was used and the search was conducted in different databases (Scopus, Web of Science, PubMed). A total of 23 articles were examined and classified according to year of publication, ambulatory/non-ambulatory subjects, and IMU positioning on human body. The analysis points out the recent regulatory identification of Stride Velocity 95th Centile as a new endpoint in therapeutic DMD trials when measured continuously from a wearable device, while only a few studies proposed the use of IMUs in non-ambulatory patients. Clinical recognition of reliable and accurate outcome measures for the upper body is still a challenge
Tipologia CRIS:
03B-Review in Rivista / Rassegna della Lett. in Riv. / Nota Critica
Keywords:
Duchenne muscular dystrophy; inertial measurement units; wearable devices; outcome measures; movement disorders
Elenco autori:
Panero E.; D'Alessandro R.; Cavallina I.; Davico C.; Mongini T.; Gastaldi L.; Ricci F.
Autori di Ateneo:
CAVALLINA ILARIA
DAVICO Chiara
MONGINI Tiziana Enrica
PANERO Elisa
RICCI Federica Silvia
Link alla scheda completa:
https://iris.unito.it/handle/2318/1893513
Link al Full Text:
https://iris.unito.it/retrieve/handle/2318/1893513/1096388/applsci-13-01268-v2%20(1).pdf
Pubblicato in:
APPLIED SCIENCES
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 25.6.1.0