Fluence Beam Monitor for High-Intensity Particle Beams Based on a Multi-Gap Ionization Chamber and a Method for Ion Recombination Correction

Articolo
Data di Pubblicazione:
2022
Abstract:
Featured Application Beam monitor for high intensity beams in particle therapy. This work presents the tests of a multi-gap detector (MGD), composed of three parallel-plate ionization chambers (ICs) with different gap widths, assembled to prove the capability of correcting for charge volume recombination which is expected to occur when high fluence rates are delivered. Such beam conditions occur with a compact accelerator for charged particle therapy developed to reduce the costs, to accomplish faster treatments and to exploit different beam delivery techniques and dose rates as needed, for example, for range modulation and FLASH irradiations, respectively. The MGD was tested with carbon ions at the Centro Nazionale di Adroterapia Oncologica (CNAO Pavia, Italy), and with protons in two different beam lines: at Bern University Hospital with continuous beams and at the Laboratori Nazionale del Sud (Catania, Italy) of the Italian National Center of Nuclear Physics (INFN) with pulsed beams. For each accelerator, we took measurements with different beam intensities (up to the maximum rate of ionization achievable) and changed the detector bias voltage (V) in order to study the charge collection efficiency. Charge recombination models were used to evaluate the expected collected charge and to measure the linearity of the rate of ionization with the beam fluence rate. A phenomenological approach was used to determine the collection efficiency (f(1)) of the chamber with thinnest gap from the relative efficiencies, f(1)/f(2) and f(1)/f(3), exploiting the condition that, for each measurement, the three chambers were exposed to the same rate of ionization. Results prove that two calibration curves can be determined and used to correct the online measurements for the charge losses in the ICs for recombination.
Tipologia CRIS:
03A-Articolo su Rivista
Keywords:
online beam monitor; ionization chambers; particle therapy; large beam intensities; flash therapy
Elenco autori:
Giordanengo, S; Guarachi, LF; Braccini, S; Cirrone, GAP; Donetti, M; Fausti, F; Milian, FM; Romano, F; Vignati, A; Monaco, V; Cirio, R; Sacchi, R
Autori di Ateneo:
CIRIO Roberto
MONACO Vincenzo
SACCHI Roberto
VIGNATI Anna
Link alla scheda completa:
https://iris.unito.it/handle/2318/1889852
Link al Full Text:
https://iris.unito.it/retrieve/handle/2318/1889852/1083536/Giordanengo_applsci_2022.pdf
Pubblicato in:
APPLIED SCIENCES
Journal
  • Dati Generali

Dati Generali

URL

https://www.mdpi.com/2076-3417/12/23/12160
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 25.6.1.0